Radiopharmaceutical Chemistry: New Chemistry-Other

Novel Radiolabeling Approaches

A novel prosthetic group for site-selective labeling of peptides for positron emission tomography

Dag Olberg1, Ole Hjelstuen1, Magne Solbakken2, Joseph Arukwe2, Karlsen Hege2 and Alan Cuthbertson2

1 Department of Pharmaceutics & Biopharmaceutics, University of Tromsø, Tromsø, Norway; 2 GE Healthcare, Medical Diagnostics Discovery Research, Oslo, Norway

180

Objectives: The purpose of this study was to investigate a novel chemoselective ligation reaction comprising conjugation of an [18F]-N-methylaminooxy-containing prosthetic group to functionalized peptides.

Methods: Twelve derivatives of general formula R1-CO-NH-Lys-Gly-Phe-Gly-Lys-OH were synthesized where R1 was selected from a short-list of moieties anticipated to be reactive towards the N-methylaminooxy group. Conjugation reactions were initially carried out with non-radioactive precursors, only the most promising pairings progressing to full radiochemical assessment with 18F.

Results: Best results were obtained for the ligation of O-[2-(2-[18F]fluoroethoxy)ethyl]-N-methyl-N-hydroxylamine to the maleimidopropionyl-Lys-Gly-Phe-Gly-Lys-OH precursor in acetate buffer (pH 5) after 1 h at 70 °C. The non-decay-corrected isolated yield was calculated to be 8.5 %. The most encouraging result was observed with 4-(2-nitrovinyl)benzoyl-Lys-Gly-Phe-Gly-Lys-OH, where the conjugation reaction proceeded rapidly to completion at 30 °C after only 5 min. The corresponding non-decay corrected radiochemical yield for the isolated 18F-labeled product was 12 %. The preliminary results from this study demonstrate the considerable potential of this novel strategy for the radiolabeling of peptides.

Conclusions: 18F-Containing N-methylaminooxy compounds are useful prosthetic groups suitable for labeling of peptides. The 4-(2-nitrovinyl)benzoyl moiety covalently linked to a model peptide was found to be highly reactive and selective towards the prosthetic group enabling efficient labeling at 30 °C after 5 minutes in sodium acetate buffer at pH 5. This protocol therefore represents a novel methodology for the radiolabeling of peptides.





This Article
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Google Scholar
Right arrow Articles by Olberg, D.
Right arrow Articles by Cuthbertson, A.
PubMed
Right arrow Articles by Olberg, D.
Right arrow Articles by Cuthbertson, A.