Improved image quality in small-animal gated cardiac SPECT using non-rigid motion compensation

Jason Parker1, David Gilland1, Freek Beekman2 and Brendan Vastenhouw2

1 Nuclear and Radiological Eng., U of Florida, Gainesville, Florida; 2 Image Sciences Inst., University Medical Center Utrecht, Utrecht, Utrecht, Netherlands


Formula

101

Objectives: The objective of this work was to improve small-animal gated cardiac SPECT images using a new non-rigid motion estimation method combined with temporal summation.

Methods: Gated cardiac images of a mouse were obtained using a stationary SPECT system with 75 focusing 0.6mm pinholes (U-SPECT-II, MILabs, The Netherlands). The non-rigid motion between reconstructed image frames was estimated using a new method that generalizes a standard optical flow algorithm into a successive quadratic approximation framework. The method has demonstrated improved motion estimation accuracy. Using the estimated frame-to-frame motion, all frames were deformed to a reference frame and summed to achieve reduced image noise with limited motion blur.

Results: The proposed method generated images of superior image quality to the original, uncompensated images. Specifically, (i) the right ventricular wall now stayed visible throughout the cardiac cycle, (ii) a lower overall noise level was achieved, and (iii) the papillary muscles showed improved definition.

Conclusions: We have developed a method for improving the image quality of small-animal gated cardiac SPECT images using non-rigid motion estimation combined with temporal summing. Future work will concentrate on implementation of the method into a maximum a posteriori reconstruction framework.

Research Support: This work was supported by the National Inst. of Health under Grant RO1HL073336, and the United States Army Medical Research and Material Command under Award No. W81XWH-04-1-0594.





This Article
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Google Scholar
Right arrow Articles by Parker, J.
Right arrow Articles by Vastenhouw, B.
PubMed
Right arrow Articles by Parker, J.
Right arrow Articles by Vastenhouw, B.